User Manual
THE STANDARD IN PRECISION MEASUREMENT
Professional Thermocouple Thermometer
with Dual Type K Inputs, Data Logging,
and Optional Infrared Wand
with NIST-Traceable Calibration
Model 20250-19
DIF
Enter
REC
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - Model 20250-19

User ManualTHE STANDARD IN PRECISION MEASUREMENT Professional Thermocouple Thermometer with Dual Type K Inputs, Data Logging, and Optional Infrared

Strona 2 - Key Features

10SpecificationsRangeTemperature, external type K thermocouple–328 to 2501°F (–200 to 1372°C)ResolutionTemperature display 0.1 (<1000) or 1 (≥1000)A

Strona 3 - Meter Description

11Maintenance, Recalibration, and RepairCleaning and storage• The meter should be cleaned with a damp cloth and mild detergent when necessary. Do not

Strona 4 - Setup and Operation

For Product and Ordering Information, Contact:Toll-Free: 1-800-323-4340 Phone: 1-847-549-7600 Fax: 1-847-247-2929 ColeParmer.com/Digi-SenseToll-Free:

Strona 5

2IntroductionThe Digi-Sense Professional Thermocouple Thermometer (Model 20250-19) with Dual Type K Inputs, Data Logging, and Optional Infrared Wand

Strona 6

3 DIFEnterRECMeter Description 1. Thermocouple type K (T1) input 2. Thermocouple type K (T2) input 3. LCD 4. Enter button 5. Up  button 6. Rec/ butt

Strona 7

4Setup and Operation1. Press Power on/off button to turn the unit on. The value immediately shown is the number of data logging sample points remai

Strona 8 - Fig. 5. Display shows 18,000

5Changing Setup Options Use the Setup mode to change offset, sample rate, time, clear data logging memory, and sleep mode settings. The thermometer st

Strona 9 - Software Installation

6Sample Rate FunctionThe tertiary display shows the sample rate of the temperature data recording. When the meter is powered on, the default sample ra

Strona 10 - Specifications

73. Press Enter button and “SURE No” will appear on the screen. 4. Press the  or Rec/ button until the display shows “SURE YES”, indicating the

Strona 11

8Recording/Data Logging Operation (Meter)1. Press Power on/off button to turn the unit on. The first value immediately shown is the number of data l

Strona 12 - 1065DGMAN_20250-19 Rev.1

97. To download the data to your PC, select RealTime(R) in the menu bar and click run. The software screen will display the data being downloaded fro